Installation Instructions
CONNECTING A GAS DRYER (cont.)
GAS REQUIREMENTS
WARNING
•Installation must conform to local codes and ordinances or, in their absence, the
NATIONAL FUEL GAS CODE, ANSI Z223.
•This gas dryer is equipped with a Valve and Burner Assembly for use only with natural gas. Using conversion kit
•The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0.5 PSI (3.4 KPa).
•The dryer must be isolated from the gas supply piping system by closing the equipment
DRYER GAS SUPPLY CONNECTION
2″ |
|
(5.1 cm) |
|
25⁄8″ (6.7 cm) | 3/8″ NPT MALE THREAD GAS SUPPLY |
NOTE: Add to vertical dimension the distance between cabinet bottom to floor.
GAS SUPPLY
•A 1/8″ National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping.
•Supply line is to be 1/2″ rigid pipe and equipped with an accessible shutoff within 6 feet of, and in the same room with, the dryer.
•Use pipe thread compound appropriate for natural or LP gas or use Teflon® tape.
•Connect flexible metal connector to dryer and gas supply.
IN THE COMMONWEALTH
OF MASSACHUSETTS
•This product must be installed by a licensed plumber or gas fitter.
•When using
•A flexible gas connector, when used, must not exceed 3 feet.
ADJUSTING FOR ELEVATION
•Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft. elevation.
For operation at elevations above 2000 ft., input ratings should be reduced at a rate of 4 percent for each 1000 ft. above sea level.
•Installation must conform to local codes and ordinances or, in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.