REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION

Installation Instructions

REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION

Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.

The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.

Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

either side

front and rear03

Minimum vertical space from floor tooverhead shelves, cabinets, ceilings, etc., is 52 .

Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.

The closet should be vented to the outdoors to prevent gas pocketing in case of gas in the supply line.

No other fuel-burning appliance shall be installed in the same closet with the dryer (gas models only).

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.

BATHROOM OR BEDROOM

INSTALLATION

The dryer MUST be vented to the outdoors. See

EXHAUSTING THE DRYER.

The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers).

MOBILE OR MANUFACTURED HOME INSTALLATION

The installation must conform to the

MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32–80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME,

NO. 501B.

The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure. (See EXHAUSTING THE DRYER.)

The vent MUST NOT be terminated beneath a mobile or manufactured home.

The vent duct material MUST BE METAL.

FOR GAS MODELS ONLY: KIT 14-D346-33 MUST be used to attach the dryer securely to the structure.

FOR GAS MODELS ONLY: The vent MUST NOT be connected to any other duct, vent or chimney.

Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent.

Provide an opening with a free area of at least 25 sq. in. for introduction of outside air into the dryer room.

15