TROUBLESHOOTING

E-3

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Thermal LED is lit.

1. Machine’ s

thermostat

has

 

 

 

 

opened. Check for proper fan

 

 

 

 

operation. There are two main

 

 

 

 

fans in the PowerWave AC/DC.

 

 

 

 

One machine is located in the

 

 

 

 

lower portion of the machine

 

 

 

 

which should be running when-

 

 

 

 

ever the machine is on. The

 

 

 

 

other fan is located in the upper

 

 

 

 

portion of the machine and only

 

 

 

 

runs when the machine is trig-

 

 

 

 

gered. Check for material block-

 

 

 

 

ing intake or exhaust louvers, or

 

 

 

 

for excessive dirt clogging coo-

 

 

 

 

ing channels in machine.

 

 

 

 

 

2. DC Bus PC board thermostat

 

 

 

 

has opened check for excessive

 

 

 

 

load on 40VDC supply.

 

 

 

 

 

3. Be sure process does

not

 

 

 

 

exceed duty cycle limit of the

 

 

 

 

machine.

 

 

If all recommended possible areas

 

Machine won’t weld, can’t get any

1. Input voltage is too low or too

 

output. (CR1 will not pull in.)

high. Make certain that input

of misadjustments have been

 

 

 

voltage is proper, according to

checked and the problem persists,

 

 

 

the Rating Plate located on the

contact your local Lincoln

 

 

 

rear of the machine.

 

Authorized Field Service Facility.

 

 

 

2. If the Thermal LED is also lit,

 

 

 

 

see “Yellow Thermal LED is Lit”

 

 

 

 

section.

 

 

 

 

 

 

3.Primary current limit has been

 

 

 

 

exceeded. Possible short in out-

 

 

 

 

put circuit. Turn machine off.

 

 

 

 

Remove all loads from the output

 

 

 

 

of the machine. Turn back on. If

 

 

 

 

condition persists, turn power off,

 

 

 

 

and contact

an authorized

 

 

 

 

Lincoln Electric Field Service

 

 

 

 

facility.

 

 

 