Image 11

8)Remove 2 screws from brush wraparound cover. Loosen and rotate the wraparound cover until neg- ative brushholder is exposed. (Large flat head screwdriver and pliers).

9)The negative brushholder is in the 11:00 position looking at the control panel end of the generator. Remove negative brushholder 5/16” bolt. (1/2” Socket, ratchet, and small extension.)

10)(NOTE:) If you are installing the WFM on the Classic I, you must change the “250H” thermostat to the thermostat marked “200”, (provided in the mounting hardware packet). Make certain the nut and bolt is tightened and the 608 and 609 leads are connected to the thermostat. (1/2” Socket, ratchet, and 1/2” open end.)

11)Position Wire Feed Module control box next to the right side of the machine (as shown). Place one plain washer (provided in the mounting hard- ware packet) over each mounting stud.