TROUBLESHOOTING

 

TROUBLE

 

 

CAUSES

 

 

WHAT  TO  DO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Machine has no output

 

 

a.

Electrode or work lead loose or

 

 

 

 

 

 

 

 

 

 

 

 

a.

Repair Connection.

 

 

 

 

with machine switch in

 

 

 

broken.

 

 

 

 

 

 

 

 

 

CV mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b.

No generator output.

 

 

b. Refer to quick check procedure for

 

 

 

 

 

 

 

 

 

 

generator only.

 

 

 

 

 

 

 

c.

CR4 is not working, or no input to

 

 

c. Refer to procedure for Checking the

 

 

 

 

 

 

CR4.

 

 

 

Cold Tip Contactor (CR4).

 

 

 

 

 

 

d.

Protective circuits operating due to

 

 

d.

Turn engine off. Remove short

 

 

 

 

 

 

output short circuit.

 

 

 

circuit.

 

 

 

 

 

 

 

 

e.

Broken or loose wiring connec-

 

 

e.

Broken or loose connections from

 

 

 

 

 

 

tions.

 

 

 

WFM to control panel and engine

 

 

 

 

 

 

 

 

 

 

welder. Refer to wiring diagram to

 

 

 

 

 

 

 

 

 

 

check.

 

 

 

 

 

 

 

 

f.

Defective P.C. Board

 

 

f.

Refer to P.C. Board Troubleshooting

 

 

 

 

 

 

 

 

 

 

Procedure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Machine has minimum

 

 

a.

No shunt field voltage.

 

 

a.

In CV mode, check for 10-60 VDC

 

 

output and no control.

 

 

 

 

 

 

 

across pin 8 of J3 and pin 1 of J4 on

 

 

 

 

 

 

 

 

 

 

WFM P.C. Board.

 

 

 

 

 

 

 

 

 

 

 

 

-- Check for loose or broken

 

 

 

 

 

 

 

 

 

 

connections in wiring harness.

 

 

 

 

 

 

 

 

 

 

-- Refer

to

P.C.

Board

 

 

 

 

 

 

 

 

 

 

Troubleshooting Procedure.

 

 

 

 

 

 

b.

Excessive current, thermal shut-

 

 

b.

Remove load and allow machine to

 

 

 

 

 

 

down.

 

 

 

cool down.

If output returns after

 

 

 

 

 

 

 

 

 

 

cool down, reduce output or duty

 

 

 

 

 

 

 

 

 

 

cycle.

 

 

 

 

 

 

 

 

 

 

 

 

 

-- Check for continuity at quick con-

 

 

 

 

 

 

 

 

 

 

nects between leads 609 and 608

 

 

 

 

 

 

 

 

 

 

inside the WFM.

 

 

 

 

 

 

 

 

 

 

 

 

-- Check wiring harness with these

 

 

 

 

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

 

 

 

 

 

-- Check continuity of the thermostat

 

 

 

 

 

 

 

 

 

 

located on the generator negative

 

 

 

 

 

 

 

 

 

 

brushholder.

 

 

 

 

 

 

 

c.

Open in feedback circuitry.

 

 

c.

Check in-line connector, P.C. Board,

 

 

 

 

 

 

 

 

 

 

and wiring harness plugs, especially

 

 

 

 

 

 

 

 

 

 

leads 667 and 621.

 

 

 

 

 

 

 

d.

Voltage adjust potentiometer circuit

 

 

d.

Refer to procedure for checking

 

 

 

 

 

 

open or misconnected.

 

 

 

Voltage Control Potentiometer on

 

 

 

 

 

 

 

 

 

 

Machine. Check wiring of lead num-

 

 

 

 

 

 

 

 

 

 

bers 75, 76, and 77.

 

 

 

 

 

 

 

e.

Defective P.C. Board.

 

 

e.

Refer to P.C. Board Troubleshooting

 

 

 

 

 

 

 

 

 

 

Procedure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 