E-8

TROUBLESHOOTING

E-8

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ʻErʼ is displayed on power up.

1.

EEPROM error detected.

 

 

2.

Damaged control p.c. board.

 

 

 

 

 

ʻGLPʼ is displayed.

1.

Ground Loop Protection fault

 

 

 

occurred

 

 

2.

GLP reed switch failure.

 

 

3.

Damaged control p.c. board.

 

 

 

 

 

After pressing the trigger, wire

1.

Power source work & electrode

 

feeds for a couple seconds, but

 

sense lead polarity switch or

 

stops. The voltage display reads

 

jumper is not correctly set.

 

less than 8.0 volts while the wire is

 

 

 

feeding.

2.

Damaged wiring between the con-

 

 

 

trol p.c. board and the work and

 

 

 

electrode connections.

 

 

3.

Damaged control p.c. board

 

 

 

 

If all recommended possible areas

 

 

 

of misadjustment have been

The knobs do not control the com-

1.

Limits are set for wire feed speed

checked and the problem persists,

plete range of wire feed speed or

 

or voltage.

Contact your local Lincoln

voltage.

2.

DIP switch S1 is incorrectly set for

Authorized Field Service Facility.

 

 

 

 

the wrong wire drive or gear ratio.

 

 

3.

Improper power source selection

 

 

 

on the control p.c. board.

 

 

 

 

Gas solenoid not operating properly

1. Inlet gas pressure exceeding 80

 

or intermittent.

 

psi(5.5 bar). Verify that gas pres-

 

 

 

sure regulator is operating proper-

 

 

 

ly.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.