TROUBLESHOOTING | ||
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
| Speed does not change when weld | 1. | ||
| current flows. |
| to the same value. | |
|
| 2. | Current sensing reed switch is not | |
|
|
| operating properly. | |
|
| 3. | The wiring from the control p.c. | |
|
|
| board to the weld current sensing | |
|
|
| reed switch is damaged. | |
|
| 4. | Damaged control p.c. board. | |
|
|
|
| |
| Voltmeter does not function proper- 1. | The work sense lead (#21) or the | ||
| ly. Welding may or may not vary |
| electrode sense lead (#67) may | |
| from normal procedure. Wire feeds |
| have intermittent or poor connec- | |
| properly. |
| tions. | |
|
| 2. | Improper power source selection | |
|
|
| on the control p.c. board. | |
|
| 3. | Control p.c. board failure. | |
|
|
|
|
|
| Cold feed forward or cold feed | 1. | The connector from the control | |
| reverse buttons on keypad do not |
| p.c. board to the display p.c. | |
| work, but motor control otherwise |
| board or the connector from the | |
| functions properly. |
| display p.c. board to the keypad | |
|
|
| are loose or improperly inserted. | |
|
| 2. | Damaged keypad | |
|
| 3. | Damaged display p.c. board. | |
|
| 4. | Damaged control p.c. board. | |
|
|
|
|
|
| Gas purge key does not operate | 1. | The connector from the control | |
| the gas solenoid, but gas flow does |
| p.c. board to the display p.c. | |
| occur while welding. |
| board or the connector from the | |
|
|
| display p.c. board to the keypad | |
|
|
| are loose or improperly inserted. |
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
2.Damaged keypad
3.Damaged display p.c. board.
3.Damaged control p.c. board.
CAUTION