SCH Colllectorsrs Instalst llation & Operationti Manuall
3 Roof Attachment Installation
Roof attachment types
Table 3A Roof Fastenings - Parts
|
|
| SOLAR ROOF MOUNTS |
| Installation Type |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Parallel |
| Inclined |
| Free- | See |
|
| Description |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Lochinvar |
|
|
|
|
|
| standing | Page |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Part # |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
| Name |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| BOLT, |
|
|
|
|
|
|
|
|
| Stainless steel attachment for universal heavy duty | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| X |
| X |
| X | 13 | installations, | on parallel | and | inclined | roofs | and | ||||||||
|
|
|
|
|
|
|
| SRM20001 | DOUBLE |
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| freestanding | installations | on | sufficiently | anchored | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| HANGER |
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| bases. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ANCHOR, |
|
|
|
|
|
|
|
|
| Stainless steel attachment | for | parallel | and | inclined | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| X |
| X | - | 15 | installations on various types of tiled roofs. Standard | ||||||||||||||
|
|
|
|
|
|
|
| SRM20003 | RAFTER, STD |
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| installations for tile heights of up to 1.5". Package is | |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ROOF TILE |
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| complete with fasteners and spacers. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ANCHOR, |
|
|
|
|
|
|
|
|
| Stainless steel attachment | for | parallel | and | inclined | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| X |
| X | - | 15 | installations on various types of tiled roofs. Standard | ||||||||||||||
|
|
|
|
|
|
|
| SRM20004 | RAFTER, TALL |
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| installations for tile heights of up to 2". Package is | |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ROOF TILE |
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| complete with fasteners and spacers. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HOOK, FLAT |
|
|
| - |
| - |
| Stainless steel attachment for parallel installations on | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
| SRM20005 |
| X |
| 16 | plain tile, slate, and flat cement tiled roofs with pitches | ||||||||||||||||||
|
|
|
|
|
|
|
| TILE |
|
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| in excess of 30 degrees. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Stainless steel attachment for parallel and inclined | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| SRM20006 | CLAMP, JOINT |
| X |
| X | - | 18 | installations | on jointed tin, galvanized, or | copper | |||||||||||||
|
|
|
|
|
|
|
|
|
| roofs. Additional securing | cables | (Lochinvar | Part # | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SRM20012) are required for inclined installations. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PLATE, |
|
|
|
|
|
|
|
|
| Galvanized steel attachment for parallel, inclined and | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| SRM20007 | FLANGE, |
| X |
| X |
| X | 20 | freestanding installations on asphalt or elastomer | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
| SHINGLE, STD. |
|
|
|
|
|
|
|
|
| roofs. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PLATE, |
|
|
|
|
|
|
|
|
| Galvanized | steel | attachment | for inclined | and | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
| FLANGE, | - |
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| SRM20008 |
|
| X |
| X | 22 | freestanding installations on asphalt or elastomer | ||||||||||||||||
|
|
|
|
|
|
|
| SHINGLE, |
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| RAISED |
|
|
|
|
|
|
|
|
| roofs. Also recommended for flat roofs. |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| BOLT, |
|
|
|
|
|
|
|
|
| Galvanized steel attachment for inclined or freestanding | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
| ANCHOR, | - |
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| SRM20009 |
|
| X |
| X | 26 | installations with 2.75" height adjustment. For use in | ||||||||||||||||
|
|
|
|
|
|
|
| CONCRETE W/ |
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ADJ |
|
|
|
|
|
|
|
|
| applications with no more than a 5 degree inclination. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| BOLT, |
|
|
|
|
|
|
|
|
| Galvanized | steel | attachment |
| for | inclined | or | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| - |
|
| X |
| X | 26 | freestanding installations with no height adjustment. | |||||||||||||
|
|
|
|
|
|
|
| SRM20010 | ANCHOR, |
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| For use in applications with no more than a 5 degree | ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| CONCRETE |
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| inclination. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| KIT, UNIV |
|
|
|
|
|
|
|
|
| Stainless steel cable set for securing | collectors on | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
| - |
|
| X | - | 19 | inclined jointed roofs. Kit includes |
| cable, turnbuckle, | ||||||||||||
|
|
|
|
|
|
|
| SRM20012 | CABLE |
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
| hardware for attachment to frame, and joint clamp. | |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| SECURING |
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For inclined installations only. |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ATTACHMENT, |
| X |
| X | - | 23 | Stainless steel attachment for parallel and inclined | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
| SRM20013 | ROOF CORR |
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| installations on profiled and corrugated roofs. |
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| METAL |
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ATTACHMENT, |
|
|
|
|
|
| - |
| Galvanized | steel | attachment | for | installations | on | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
| SRM20014 | WAVE ROOF |
| X |
| X | 25 | concrete corrugated roofs with 5 corrugations per | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| SM |
|
|
|
|
|
|
|
|
| meter. For parallel and inclined installations. |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ATTACHMENT, |
|
|
|
|
|
| - |
| Galvanized | steel | attachment | for | installations | on | ||||||
|
|
|
|
|
|
|
|
| SRM20015 | WAVE ROOF |
| X |
| X | 25 | concrete corrugated roofs with 8 corrugations per | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
| LG |
|
|
|
|
|
|
|
|
| meter. For parallel and inclined installations. |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10