Figure 3-1Spacing Distance

SCH Collectors Installation & Operation Manual

3 Roof Attachment Installation

Figure 3-1Spacing Distance

a

a

=

a

= = = =  = =

a = 2 - 10 in.

x

a

X

55 - 63 in.

Spacing Distance

Equally space the center roof attachments starting in the middle, the two (2) end attachments will be spaced according to the inner measurement (start in the middle and work outwards). The remaining roof mounts should be equally spaced in between the two (2) end roof attachments.

Note: For multiple collector installations reference the Collector Mounting Section of this manual for spacing between collectors.

Each collector will have its own independent substructure set. Ensure there is ample room on the chosen roof area for the number of collectors chosen.