Figure 3-20 Cable Angle

SCH Collectors Installation & Operation Manual

3 Roof Attachment Installation

4.

Choose a cable orientation to ensure proper degree of

 

Figure 3-20 Cable Angle

 

angle (see FIG. 3-18).

5.

Install the steel cable on the A-frame bracket using the

 

 

pin and pin clip provided in the kit (see FIG. 3-19).

 

Figure 3-18Cable Orientations

Flange plate shingle (standard) #SRM20007

The standard flange shingle plate is used for parallel and inclined installations on asphalt and elastomer roofs.

Figure 3-19Install Steel Cable on A-frame

INSERT PIN

 

USE PIN CLIP TO SECURE

 

 

 

 

THE CABLE

￿CAUTION

The plates must be screwed into a support capable bearing the required load (generally rafters or concrete).

Once installed, the plates must be sealed to the roof sheet material (see FIG. 3-24), and only then can the collector be fitted.

CABLE (TURNBUCKLE)

INSTALL CABLEINSTALLED (TURNBUCKLE)

6.Attach the steel cable to the joint clamp (fashioned after the cable orientations in FIG. 3-18.

NOTICE Extend turnbuckle to its fullest extent.

7.Before tightening the joint clamp, set the angle of the cable to greater than or equal to 30°, but less than or equal to 45° (see FIG. 3-20).

8.Tighten the joint clamp.

9.Use the turnbuckle to tighten the cable.

Unpacking and checking parts

When unpacking the system, check the model names of the components of each system and check to be sure you have the correct number of parts (see FIG. 3-21).

Figure 3-21Kit #SRM20007 - Flange Shingle Plate (Standard) Kit Components

PLATE FLANGE (STD) (1X)

SCREW (M10) (4X)

SCREW (M6) (4X)

SQUARE DISK (1X)

HEX NUT (M8) (1X)

HEX BOLT (M8) (1X)

WASHER (M8) (1X)