LIVE 240 VOLTS | NEUTRAL 0 VOLTS |
NEUTRAL 0 VOLTS |
|
|
| A |
L1 | L2 | L3 |
N |
| E |
6 7 8 E |
| E F 9 10 |
T1 | T2 | T3 |
LOAD
Electrical Wiring Source To Front Panel Models—240 volts (Foreign)
1.Unfasten the front panel on control box and swing the door open.
2.Locate the disconnect. It is the black plastic switch located on the top center of the box.
3.Remove screw A and slip off the cover.
4.Connect a 0V lead to the neutral position and the 240V lead to the live position.
5.Connect the ground wire to the same position as the machine ground (the green/yellow wire).
6.Replace the protective cover.
7.Close and secure the front panel.
Coolant
1.Check the coolant reservoir and remove any foreign objects.
2.Be sure the drain hose is routed through the hole in the lid of the coolant tank.
3.Fill the tank with clean water, adding the proper amount of
CAUTION
FAILURE TO USE AN
11