Lopi Liberty Wood Stove Stove Installation for qualified installers only, Travis Industries

Models: Liberty Wood Stove

1 38
Download 38 pages 28.19 Kb
Page 15
Image 15
Exterior Factory Built Chimney

Stove Installation (for qualified installers only)

15

Exterior Factory Built Chimney

NOTE:

Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained)

Chimney Cap

 

 

Follow the chimney

 

 

manufacturer's

(See the section "Chimney

 

 

 

}

instructions and

Termination Requirements"

clearances for roof

for more details)

 

 

penetrations. A storm

 

 

Chimney Sections

collar and flashing are

required (some

 

 

Minimum Air Space to

 

require a radiation

Combustibles (See

 

shield).

Chimney Manufacturer's

Wall Bands

Minimum 15'

Instructions - usually 2")

and

Maximum 33'

 

Supports

 

 

 

Min. 18"

 

Insulated Tee

clearance to

 

(with cleanout )

ceiling

}

Follow the chimney

 

 

manufacturer's

Chimney Connector

instructions and

 

 

 

 

clearances for wall

 

 

 

 

 

 

penetrations. A

 

 

 

wall radiation shield

Floor Protection

 

 

(thimble) is

(See "Floor

 

Stove Clearances

required.

Protection

 

 

 

(See the section "Stove

Optional

Requirements"

 

 

Placement Requirements"

insulated

for details)

 

 

for more details)

chase

 

 

Hearth Stove

Positive

Connection

NOTE:

Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support

 

Figure 12

 

Cap and flashing

 

prevents water from

NOTE: The entire fireplace and

entering

 

chimney must be clean, undamaged,

 

and meet all local building codes

 

(UBC, etc.). Damage must be

 

repaired prior to installation. The

 

chimney must be 15' to 33' tall.

 

 

The liner must be

 

stainless steel connector

 

or flexible vent. Follow

 

the liner manufacturer's

 

instructions for installation

 

and support.

Combustible

 

Mantle

 

Min. 18"

Airtight Insulated

 

 

Clean-Out

 

Remove damper

 

or wire it open

Floor Protection

 

(See the section

 

"Floor Protection

 

Requirements"

See the section

for more details)

"Stove Placement

 

Requirements" for

 

minimum clearances

 

required.

 

Figure 13

© Travis Industries

100-01164

4041115

Page 15
Image 15
Lopi Liberty Wood Stove Stove Installation for qualified installers only, Exterior Factory Built Chimney, 100-01164