Lopi Liberty Wood Stove Alcove Installation Requirements, Travis Industries, 100-01164, 4041115

Models: Liberty Wood Stove

1 38
Download 38 pages 28.19 Kb
Page 12
Image 12
Alcove Installation Requirements

12

Stove Installation (for qualified installers only)

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the special installation requirements listed below must be met.

Chimney connector and chimney must be one of the following types:

AMERI-TEC model DCC with model HS chimney

DURAVENT model DVL with DURATEC or DURA-PLUS chimney

METALFAB model DW connector with TG chimney

SECURITY model DP connector with SECURITY model ASHT or S2100 chimney

Standard Masonry Chimney with any one of the above listed connectors

NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.

Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete - see Figure 7). This non-combustible material must be spaced and ventilated at least 1" off of all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling. All other alcoves are considered combustible. The clearances below must be met:

Minimum Clearance

Combustible

Non-Combustible

(See the Figure 7 below)
Alcove

Alcove

 

 

 

 

A

Sidewall to stove

16"

6"

B

Backwall to stove

10"

2"

D

Connector to sidewall

27-1/2"

17-1/2"

E

Connector to backwall

12-3/4"

4-3/4"

G

Maximum depth of alcove

48"

48"

H

Minimum width of alcove

62"

42"

J

Minimum height of alcove

84"

6" above stove top

Non-combustible alcove construction (on walls and ceiling) - see the explanation above

Ventilated air space

3 1/2" thick non- combustible material

1" Min.

Combustible materials

Non-combustible reinforcer

d

e

a

b

j

h

g

Figure 7

© Travis Industries