Installation7
Clearances
•Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the heater.
•Insert must be placed a minimum 9" from a side wall (or combustible protruding more than 3/4").
Mantel Requirements
•The mantel (combustible or
Hearth Requirements
•The
Facing Requirements
•The
Placing the Insert
•The insert must be placed within an undamaged masonry or factory built (metal) fireplace. Loose bricks or other damage must be fixed. Clean the fireplace before installing.
•A 3/8" gap must be allowed between the surround panels and the face of the fireplace.
The vent should be routed to the fireplace prior to installing the insert. See the section "Vent Installation" for details on vent location.
The insert must protrude
Apply the "This fireplace has been altered..." sticker to the fireplace. You may wish to place it in a location where it will be covered by the surround panels.
Use the leveling bolts for fireplaces with recessed floors (included with the insert). Screw them into the baseplate from below.
Run the power cord to the side along the front of the fireplace (do not route it under the insert).
Travis Industries | 4 0 5 1 2 1 6 | 9 3 5 0 8 0 5 1 |