Installation into a Factory Built (Metal) Fireplace
Vertical Cap
Storm Collar
“L” Vent Flex Section
The smoke shelf, shields, damper, and baffles may be removed if attached with mechanical fasteners.
The firebrick (refractory) may be removed.
HINT:
Paint the interior of the fireplace with latex paint to
prevent fireplace odors from entering the home.
“L” Vent
Cover Plate
Seal the cover plate with silicone.
3/8” Gap is required between the surround panels and the front of the fireplace.
The log shelf,
screen, and doors (if present) must be removed
13” Min.
6” Min.
The metal sides, frame members, or other structural components of the factory built fireplace may not be removed or altered.
The metal floor of the firebox may be removed leaving the fireplace floor outer wrap.
Use the telescoping legs to support the insert on raised fireplaces.