–During fast charging of the battery pack: 230mA in +12V current
3.3.4.6Operating and
For the SAS 9261 RAID controllers, the operating (thermal and atmospheric) conditions are:
•Relative humidity range is 5 percent to 90 percent noncondensing (20 percent to 80 percent noncondensing for the RAID controllers)
•Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature
• Temperature range: +10 ° C to +60 ° C without battery backup unit
•Temperature range: +10 ° C to +44.5 ° C with iBBU battery backup
The parameters for the
•Temperature range: −30° C to +80° C without the battery backup unit
•Temperature range: 0° C to +45° C with the battery backup unit
3.3.5Power Supply Requirements for SAS 9280 RAID Controllers
All power is supplied to the SAS
•State 1: During a hard reset
•State 2: During a disk stress test
•State 3: While sitting idle at the DOS prompt
The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 3.13 lists the power supply for the controller for each of the three states at the different voltages.
Technical Specifications |
Copyright © 2009 by LSI Corporation. All rights reserved.