Problem

Suggested Solution

 

Firmware Initializing...

Make sure that TERMPWR is being properly

 

provided to each peripheral device populated

 

 

 

 

appears and remains on the screen.

channel.

 

 

 

 

 

Make sure that each end of the channel chain

 

 

 

is properly terminated using the recommended

 

 

 

terminator type for the peripheral device. The

 

 

 

channel is automatically terminated at the

 

 

 

MegaRAID Express 500 card if only one cable

 

 

 

is connected to a channel.

 

 

 

Make sure (on a channel basis) only two types

 

 

 

of cables are connected at any one time.

 

 

 

Make sure that the MegaRAID Express 500

 

 

 

controller is properly seated in the PCI slot.

 

What SCSI IDs can a non-hard disk

Non-hard disk devices can accommodate only

 

device have and what is maximum

SCSI IDs 1, 2, 3, 4, 5 or 6, regardless of the

 

number allowed per adapter?

channel used. A maximum of six non-hard

 

 

 

disk devices are supported per MegaRAID

 

 

 

Express 500 adapter.

 

Why does a failed logical array still

To maintain the DOS Path statement integrity.

 

get a drive assignment?

 

 

 

 

 

 

100MegaRAID Express 500 Hardware Guide