Other BIOS Error Messages
| Message | Problem | Suggested Solution |
|
Following SCSI | The physical disk roaming | Reconfigure the array. |
| |
disk not found | feature did not find the physical |
|
| |
and no empty | disk with the displayed SCSI |
|
| |
slot available for | ID. No slot is available to map |
|
| |
mapping it | the physical drive. MegaRAID |
|
| |
|
| Express cannot resolve the |
|
|
|
| physical drives into the current |
|
|
|
| configuration. |
|
|
Following SCSI | The physical drive roaming | Remove the drive or drives |
| |
IDs have the | feature found the same data on | that should not be used. |
| |
same data y, z | two or more physical drive on |
|
| |
Channel x: a, b, | channel x with SCSI IDs a, b, |
|
| |
c | and c. MegaRAID Express |
|
| |
|
| cannot determine the drive that |
|
|
|
| has the duplicate information. |
|
|
Unresolved | The configuration stored in the | Press a key to run MegaRAID |
| |
configuration | MegaRAID Express NVRAM | Manager. |
| |
mismatch | does not match the |
|
| |
between disks | configuration stored on the | Choose View/Add |
| |
and NVRAM on | drives. | Configuration from the |
| |
the adapter |
| Configure menu. |
| |
|
|
| Use View/Add Configuration |
|
|
|
| to examine both the |
|
|
|
| configuration in NVRAM and |
|
|
|
| the configuration stored on the |
|
|
|
| disk drives. Resolve the |
|
|
|
| problem by selecting one of |
|
|
|
| the configurations. |
|
|
|
|
|
|
Chapter 8 Troubleshooting | 103 |