Other BIOS Error Messages

 

Message

Problem

Suggested Solution

 

Following SCSI

The physical disk roaming

Reconfigure the array.

 

disk not found

feature did not find the physical

 

 

and no empty

disk with the displayed SCSI

 

 

slot available for

ID. No slot is available to map

 

 

mapping it

the physical drive. MegaRAID

 

 

 

 

Express cannot resolve the

 

 

 

 

physical drives into the current

 

 

 

 

configuration.

 

 

Following SCSI

The physical drive roaming

Remove the drive or drives

 

IDs have the

feature found the same data on

that should not be used.

 

same data y, z

two or more physical drive on

 

 

Channel x: a, b,

channel x with SCSI IDs a, b,

 

 

c

and c. MegaRAID Express

 

 

 

 

cannot determine the drive that

 

 

 

 

has the duplicate information.

 

 

Unresolved

The configuration stored in the

Press a key to run MegaRAID

 

configuration

MegaRAID Express NVRAM

Manager.

 

mismatch

does not match the

 

 

between disks

configuration stored on the

Choose View/Add

 

and NVRAM on

drives.

Configuration from the

 

the adapter

 

Configure menu.

 

 

 

 

Use View/Add Configuration

 

 

 

 

to examine both the

 

 

 

 

configuration in NVRAM and

 

 

 

 

the configuration stored on the

 

 

 

 

disk drives. Resolve the

 

 

 

 

problem by selecting one of

 

 

 

 

the configurations.

 

 

 

 

 

 

Chapter 8 Troubleshooting

103