| Message | Problem | Suggested Solution |
|
1 Logical Drive Degraded | A logical drive signed on | Make sure all physical |
| |
|
| in a degraded state. | drives are properly |
|
|
|
| connected and are powered |
|
|
|
| on. |
|
|
|
| Run MegaRAID Manager |
|
|
|
| to find out if any physical |
|
|
|
| drives are not responding. |
|
|
|
| Reconnect, replace, or |
|
|
|
| rebuild any drive that is |
|
|
|
| not responding. |
|
Insufficient memory to | Not enough MegaRAID | Make sure MegaRAID |
| |
run BIOS. Press any key | Express 500 memory to | Express 500 memory has |
| |
to continue… | run MegaRAID BIOS. | been properly installed. |
| |
Insufficient Memory | Not enough memory on | Make sure MegaRAID |
| |
|
| the MegaRAID Express | Express memory has been |
|
|
| adapter to support the | properly installed. |
|
|
| current configuration. |
|
|
The following SCSI IDs | The physical drives with | Make sure the physical |
| |
are not responding: | SCSI IDs a, b, and c are | drives are properly |
| |
Channel x:a.b.c | not responding on SCSI | connected and are powered |
| |
|
| channel x. | on. |
|
|
|
|
|
|
102MegaRAID Express 500 Hardware Guide