Appendix A: Modem Pooling

Table 3. 3800 Series Modem Installation — Continued

Activ (Operating)

Option

Selection

AT Command

 

 

 

 

 

Test

DTE RL (CT140)

Disable

S51=0

 

 

 

 

 

 

DTE LL (CT141)

Disable

S52=0

 

 

 

 

 

 

Test Timeout

Disable

S18=0

 

 

 

 

 

 

Rcv Remote Loop

Enable

AT&T..

 

 

 

 

 

 

V54 Address

Disable

S53=0

 

 

 

 

 

 

V54 Device Type

Peripheral

S54=0

 

 

 

 

 

Misc

StrapsWhenDisc

No_Change

S88=0

 

 

 

 

 

 

Speaker Control

OnUntilCarr

ATM..

 

 

 

 

 

 

Speaker Volume

Medium

ATL..

 

 

 

 

 

 

Access frm Remt

Enable

S55=0

 

 

 

 

 

 

Dir#1_Callback

Disable

S67=0

 

 

 

 

 

 

 

 

 

 

If you begin with the Async_Dial Factory default option settings, then the AT com- ma ds and Diagnostic Control Panel LCD command sequences to option the options are as shown in the following list:

Clear options/registers to factory default: &F0 (Configure/Factory)

DTR call control is enabled: &D2 (Configure/Edit/DTE Interface)

DSR tracks data set ready: &S1 (Configure/Edit/DTE Interface)

Numeric form (2) of result codes is enabled: V2 (Configure/Edit/DTE Dialer)

Extended Result Codes set to Use_DTE_Rate: X7 (Configure/Edit/DTE Dialer)

Long space disconnect is disabled: Y0 (Configure/Edit/Line Dialer)

MNP5 Compress is disabled: %C0 (Configure/Edit/V42/MNP/Buffer)

Dial Line Rate is set to 9600 bps: S41=3 (Configure/Edit/Dial Line)

Disable the AT Escape Char option: S2=128 (Configure/Edit/DTE Dialer)

nCommand echo is disabled: E0 (Configure/Edit/DTE Dialer)

Store option/register changes to Active(Save): &W0 (Configure/Save)

52 Issue 1 CRCS R6.0 April 1999

Page 56
Image 56
Lucent Technologies 6 manual Appendix A: Modem Pooling