Appendix A: Modem Pooling
Table 3. 3800 Series Modem Installation — Continued
Activ (Operating) | Option | Selection | AT Command | |
|
|
|
|
|
Test | DTE RL (CT140) | Disable | S51=0 | |
|
|
|
|
|
| DTE LL (CT141) | Disable | S52=0 | |
|
|
|
|
|
| Test Timeout | Disable | S18=0 | |
|
|
|
|
|
| Rcv Remote Loop | Enable | AT&T.. | |
|
|
|
|
|
| V54 Address | Disable | S53=0 | |
|
|
|
|
|
| V54 Device Type | Peripheral | S54=0 | |
|
|
|
|
|
Misc | StrapsWhenDisc | No_Change | S88=0 | |
|
|
|
|
|
| Speaker Control | OnUntilCarr | ATM.. | |
|
|
|
|
|
| Speaker Volume | Medium | ATL.. | |
|
|
|
|
|
| Access frm Remt | Enable | S55=0 | |
|
|
|
|
|
| Dir#1_Callback | Disable | S67=0 | |
|
|
|
|
|
|
|
|
|
|
If you begin with the Async_Dial Factory default option settings, then the AT com- ma ds and Diagnostic Control Panel LCD command sequences to option the options are as shown in the following list:
Clear options/registers to factory default: &F0 (Configure/Factory)
DTR call control is enabled: &D2 (Configure/Edit/DTE Interface)
DSR tracks data set ready: &S1 (Configure/Edit/DTE Interface)
Numeric form (2) of result codes is enabled: V2 (Configure/Edit/DTE Dialer)
Extended Result Codes set to Use_DTE_Rate: X7 (Configure/Edit/DTE Dialer)
Long space disconnect is disabled: Y0 (Configure/Edit/Line Dialer)
MNP5 Compress is disabled: %C0 (Configure/Edit/V42/MNP/Buffer)
Dial Line Rate is set to 9600 bps: S41=3 (Configure/Edit/Dial Line)
Disable the AT Escape Char option: S2=128 (Configure/Edit/DTE Dialer)
nCommand echo is disabled: E0 (Configure/Edit/DTE Dialer)
Store option/register changes to Active(Save): &W0 (Configure/Save)
52 Issue 1 CRCS R6.0 April 1999