Chapter 5 Installation

CAUTION: Release 4.0.1 embedded software requires a MINIMUM of 16 MB DRAM (Dynamic Random Access Memory) to run on a Cajun P550 Layer 2 supervisor module. BEFORE upgrading, ensure that the switch meets this 16 MB DRAM requirement. A memory upgrade is not required for a Cajun P550 Layer 3 supervisor module, or the Cajun P220.

NOTE: Release 4.0.1 introduces a new ASCII configuration file format that replaces the traditional binary (*.cfg) files used to store and restore saved configurations. Before upgrading the switch to Release 4.0.1, review the Installation section of these release notes.

The following memory upgrade kits are available through your local sales representative:

Table 1-3: Module Descriptions

Description

Model Number

16 MB Memory

M5500-MEM16

Upgrade Kit

 

 

 

32 MB Memory

M5500-MEM32

Upgrade Kit

 

 

 

Use the following procedure to upgrade from Release 3.1 to Release 4.0.1 of the Cajun P220, Cajun P550, or Cajun P550R switch. For more detailed installation procedures, refer to the Cajun P550/P220 Switch Installation Guide.

Downgrading to a Previous Release

1.In the CLI Configuration section of the Web Agent, click Config File Management. In the Configuration File Management dialog box, save your Release 4.0.1 Running Configuration (running.txt) to a TFTP server for potential later use.

2.From the Release 4.0.1 Enhanced CLI, clean the current configuration by issuing the nvram init command.

3.Configure the switch to select the APP that contains the previous code release.

4.Reset the switch.