Storage

When the machine is in storage for a long time, drain fuel from the fuel tank and carburetor, as follows: Drain all fuel from the fuel tank. Dispose of properly and in accordance with all local laws.

Remove the spark plug and a few drops of oil into the spark plug hole. Then, pull the starter gently, so that oil covers the engine inside and tighten the spark plug.

Clear dirt or dust from the cutter blade and outside of engine, wipe them with a oil-immersed cloth and keep the machine in a place as dry as possible.

 

 

 

Drain fuel

 

Humidity

 

 

 

Fault location

Fault

System

Observation

Cause

 

 

 

 

Engine not starting or with

Ignition system

Ignition spark O.K.

Fault in fuel supply or compression system, mechanical

difficulty

 

 

defect

 

 

 

 

 

 

No ignition spark

I-O switch operated, wiring fault or short circuit, spark

 

 

 

plug or connector defective, ignition module faulty

 

 

 

 

 

Fuel supply

Fuel tank filled

Incorrect choke position, carburetor defective, fuel

 

 

 

supply line bent or blocked, fuel dirty.

 

 

 

 

 

Compression

No compression when

Cylinder bottom gasket defective, crankshaft seals

 

 

pulled over

damaged, cylinder or piston rings defective or improper

 

 

 

sealing of spark plug

 

 

 

 

 

Mechanical fault

Starter not engaging

Broken starter spring, broken parts inside of the engine

 

 

 

 

Warm start problems

 

Tank filled ignition spark

Carburetor contaminated, must be cleaned

 

 

existing

 

 

 

 

 

Engine starts but dies

Fuel supply

Tank filled

Incorrect idling adjustment, carburetor contaminated

immediately

 

 

Fuel tank vent defective, fuel supply line interrupted,

 

 

 

 

 

 

cable or I-O switch faulty

 

 

 

 

Insufficient performance

Several systems

Engine idling poor

Air filter contaminated, carburetor contaminated, muffler

 

may simultaneously

 

clogged, exhaust duct in the cylinder clogged

 

be affected

 

 

 

 

 

 

17