MAINTENANCE

Replacing Lamp Unit

CAUTION:

Do not touch the lamp and the lamp unit immediately. It will be extremely hot. Allow at least one hour for the lamp to cool down before handling.

Do not loosen any screws except for those mentioned below.

The lamp may break if handled improperly.

Do not use other than a Marantz replacement lamp unit.

7How to replace the Lamp Unit

WARNING:

The lamp itself may get hot. Be careful when handling.

1.Press the POWER key to turn the projector off.

2.Unplug the AC power cord.

3.Wait at least one hour for the lamp and lamp unit to cool down.

4.Read the caution and warning labels on the unit.

Lamp cover

CAUTION : HIGH PRESSURE LAMP

CAUTION HOT : UNPLUG

MODEL NO. VP-12S1 / U1S

MAY EXPLODED IF IMPROPERLY HANDLED.

THE POWER CORD AND WAIT

REFER SERVICING TO QUALIFIED SERVICE

60 MINUTES BEFORE CHARGING

AC 120V 60HZ 2.0A

PERSONNEL.

THE LAMP.

 

ATTENTION : LA LAMPE SOUS

ATTENTION CHAUD :

HAUTE PRESSION PEUT SI ELLE, N'EST

DEBRANCER LE CORD ON

PAS MANIPULEE CORRECTEMENT,

D'ALOMENTION ET ATENDER

CONFIER L'OPERATION A UN

60 MINUTES AVANT DE

PERSONNEL D'ENTRETIEN QUALIFIE.

CHANGER LAMPE.

ADDITIONAL INFORMATION

5.

Loosen the lamp cover securing screw.

ENGLISH

 

6.

Remove the lamp cover.

 

7.

Loosen the two lamp housing screws.

 

 

 

(This projector has a safety switch.)

 

8.

Hold the handle then pull the lamp unit to remove.

 

9.

Install the new lamp unit.

 

10.

Secure the lamp unit with the two screws.

 

11.

Close the lamp cover and secure it with a screw driver.

 

Cleaning the lens

If the lens becomes dirty or smudged, clean it with a soft dry cloth. Use optical lens cleaners only which are approved for eyeglasses or cameras. Do not use a dampen cloth, detergent solution, or thinner. It may damage the lens and remain as stains.

Replacement parts

When replacement parts are required, be sure to inform a Marantz authorized service center. Use only replacement parts specified by Marantz. Unauthorized substitutions may result in fire, electric shock, or other hazards.

And, the warranty may not be guaranteed.

Optional accessories

CAUTION : HIGH PRESSURE LAMP

CAUTION HOT : UNPLUG

M

 

Lamp Unit

: LU-12VPS1

MAY EXPLODED IF IMPROPERLY HANDLED.

THE POWER CORD AND WAIT

7

REFER SERVICING TO QUALIFIED SERVICE

60 MINUTES BEFORE CHARGING

 

 

 

 

PERSONNEL.

THE LAMP.

 

7

Ceiling Mount KIT

: RM-12VPS1

ATTENTION : LA LAMPE SOUS

ATTENTION CHAUD :

 

 

 

 

 

HAUTE PRESSION PEUT SI ELLE, N'EST

DEBRANCER LE CORD ON

 

7

Lens

: LN-12VPS1

PAS MANIPULEE CORRECTEMENT,

D'ALOMENTION ET ATENDER

 

 

 

 

 

CONFIER L'OPERATION A UN

60 MINUTES AVANT DE

 

CAUTION:

 

PERSONNEL D'ENTRETIEN QUALIFIE.

CHANGER LAMPE.

 

 

 

 

 

 

• For ceiling installation, consult with the Marantz Authorized dealer.

21

Page 25
Image 25
Marantz VP-12S1s manual Maintenance, Replacing Lamp Unit, Cleaning the lens, Replacement parts, Optional accessories