3600 Printer Maintenance Manual

Timing

Row

Name

Formula

Min

Max

Margin

Comment

1D

Tclsa

[3,30]

3

30

 

332 Clk low to sel asserted

2V

Tco

[2,10]

2

10

 

GAL Clk to output delay

3D

Tchav

[2,39]

2

39

 

332 Clk hi to add valid

4D

Tsy

[Tsy

4

12

 

 

5C

Trah

[15, ]

15

 

<13.25>

DRAM row add hold time

6C

Taist

[5, ]

5

 

<38.50>

332 DSACK setup time

7D

Tclsn

[3,30]

3

30

 

332 Clk low to sel negated

8D

Tsy

Tsy

4

12

 

 

9V

Tpd

[3,15]

3

15

 

GAL Tpd

10C

Tasc

[0, ]

0

 

<6.25>

DRAM col add setup

11C

Tasr

[0, ]

0

 

<65.75>

DRAM row add setup

12C

Tras

[80, ]

80

 

<38>

DRAM ras low time

13C

Tds

[25, ]

25

 

<18.50>

DRAM

14V

Tsy

[4,12]

4

12

 

Sel to output HC257

15D

Tpd

Tpd

3

15

 

 

16D

Tpd

Tpd

3

15

 

 

17D

Tco

Tco

2

10

 

 

18D

Tpd

Tpd

3

15

 

 

19D

Tco

Tco

2

10

 

 

20D

Tpd

Tpd

3

15

 

 

21C

Tcas

[20, ]

20

 

<35.50>

 

22D

Tclsa

[3,30]

3

30

 

Same as 1

23C

Trp

[60, ]

60

 

<52>

 

24C

Tcah

[20, ]

20

 

<70.75>

 

25D

Tco

Tco

2

10

 

 

26D

Tpd

Tpd

3

15

 

 

27D

Tco

Tco

2

10

 

 

28D

Tchav

[2,39]

2

39

 

 

29C

Tasr

[0, ]

0

 

<65.75>

 

30D

Tco

Tco

2

10

 

 

31C

Trpc

[10, ]

10

 

<39.50>

 

32D

Tco

Tco

2

10

 

 

33D

Tco

Tco

2

10

 

 

34D

Tclsn

[3,30]

3

30

 

 

35D

Tclsa

[3,30]

3

30

 

 

36D

Tco

Tco

2

10

 

 

37C

Trp

[60, ]

60

 

<57>

 

A-12

Page 166
Image 166
Genicom 3600 manual Printer Maintenance Manual Timing, Row Name Formula Min Max Margin Comment