Remove and Replace Procedures 5

To replace the TTR supply hub and TTR supply hub adjusting plate

1.Remove the two Phillips screws securing the TTR supply hub adjusting plate to the TTR subplate and install the new adjusting plate in its place.

2.Install the thick steel washer removed in Step 5 above. Align the TTR clutch encoder with the opening in the main deck plate and slide the TTR supply hub back through the TTR clutch/encoder, the nylon washer, the motor plate, and the TTR subplate.

Note: Do not remove the motor plate or subplates. Changing the position of these plates can alter factory alignment and cause ribbon wrinkling or self-strip problems.

 

Thick

 

Nylon

washer

TTR

washer TTR clutch/

supply hub

 

encoder

 

Thin washer

Snap ring

TTR supply hub adjusting plate

3600M.056

3.Install the thin washer removed in Step 4 and the new retaining snap rings.

4.Reattach the front bezel cover. Ensure that the media access door operates properly (snaps firmly shut) after the front bezel cover is installed.

5.Align the ribbon supply hub as described in “Aligning the TTR Supply Hub” in Chapter 3.

6.Reload media (and ribbon if used) and lower the printhead.

7.Install the electronics cover, the media cover, and the power cord, and check the printer for proper operation.

5-21

Page 107
Image 107
Genicom 3600 manual Ttr