Genicom 3600 manual Adjusting the Label Mark Sensor, To position the label mark sensor

Models: 3600

1 174
Download 174 pages 13.71 Kb
Page 61
Image 61

Testing and Adjusting

3

Adjusting the Label Mark Sensor

The mark sensor detects the mark on the back of continuous media stock. The output is then used to determine the start of print point. This sensor is located under the label pathway across from the platen roller. Two adjustments affect the performance of this sensor, its physical position and sensitivity. To perform this procedure, you need the following tools:

Digital multimeter

#2 Phillips screwdriver

Small straight-slot screwdriver

To position the label mark sensor

1.Remove the media cover.

2.Use your finger to reach underneath the lower guide.

Platen roller

Locate the label mark sensor behind the platen roller near the inboard edge of the printer. Use your index finger to adjust the label mark sensor.

Inboard edge of printer.

The platen roller is not shown for clarity only.

Label mark sensor

3600M.034

3-17

Page 61
Image 61
Genicom 3600 manual Adjusting the Label Mark Sensor, To position the label mark sensor