Genicom 3600 manual Replacing the AC Plug/Input Filter, To replace the AC plug and input filter

Models: 3600

1 174
Download 174 pages 13.71 Kb
Page 117
Image 117

Remove and Replace Procedures 5

Replacing the AC Plug/Input Filter

To replace the AC plug and input filter assembly, you will need the following parts and tools:

3600 line AC plug and filter assembly, Intermec Part No. 060246-001

ESD grounding strap

#1 and #2 Phillips screwdriver

Needlenose pliers

To replace the AC plug and input filter

1.Switch off the printer power and remove the power cord, the media cover, and the electronics cover.

2.Disconnect the three push-on connectors attached to the back of the AC plug/input filter assembly.

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

I

O

Push-on connectors

AC power

plug & filter

(2 places)

3600M.062

3.Remove the two screws securing the AC plug/input filter assembly to the main deck plate and remove the assembly.

4.Install the new AC power plug and input filter assembly and secure it with the two screws removed in Step 3.

5.Reconnect the three push-on connectors removed in Step 2.

6.Install the electronics cover, the media cover, and the power cord, and check the printer for proper operation.

5-31