Table 4-1 S - Registers

 

Register

Function

Range/units Default

S0

Auto-answer Ring

0-255/rings

0

S1

Ring counter

0-255/rings

0

S2

Escape code character

0-127/ASCII

43

S3

Carriage return character

0-127/ASCII

13

S4

Line feed character

0-127/ASCII

10

S5

Backspace character

0-32, 127/ASCII

8

S6

Dial tone wait time

0-255/seconds

2

S7

Remote carrier wait time

1-255/seconds

30

S8

Comma pause time

0-255/seconds

2

S9

Carrier detect time

0-255/0.1 second

6

S10

Carrier loss time

0-255/0.1 second

14

S11

Touch-tone dialing speed

50-255/0.001 second

70

S12

Esc. character detect time

0-255/0.02 second

50

S13

Reserved

 

 

S14

Echo, response, dialing,

Bit-mapped

 

 

originate/answer

 

 

S15

Reserved

 

 

S16

Modem test options

Bit-mapped

 

S17

Reserved

 

 

S18

Modem test timer

0-255/seconds

0

S19

Reserved

 

 

S20

Reserved

 

 

S21

DTR, DCD, DSR, and

Bit-mapped

 

 

Long Space Disconnect

 

 

S22

Speaker and response

Bit-mapped

 

S23

RDL, DTE data rate,

Bit-mapped

 

 

parity,and guard tone

 

 

S24

Reserved

 

 

S25

DTR delay

0-100/seconds

5

S26

RTS/CTS delay interval

0-255/0.01 second

1

S27

Async operation, CCITT/

Bit-mapped

 

 

Bell mode

 

 

S28

Reserved

 

 

S29

Reserved

 

 

S30

Sleep mode time

0-90/seconds

10

S37

Maximum line speed

0-11

0

S90

Disconnect timer

0-255/seconds

0

S108

Retrain options

0-3

2

S109

Line Speed permitted

2-62

62

 

 

 

 

 

Section Five - Result Codes