\Bn

n=1-9

Send a 1/10 second line break to the modem,

 

 

where n = 1 to 9. At normal connect, the

 

 

default is 3

\C_

\C0

Do not buffer data during LAPM/MNP

 

 

handshaking

 

\C1

Buffer all data for 4 seconds, until receiving

 

 

200 characters or until a packet is detected

 

\C2

Do not buffer data; switch to normal mode

 

 

when fallback character is detected

\G_

\G0

Disable DCE flow control

 

\G1

Enable DCE flow control

\J_

J0

Disable serial port data rate adjustment

 

 

(keep high data rate between DTE and

 

 

modem, regardless of modem-to-modem

 

 

data rate)

 

J1

Enable serial port data rate adjustment so

 

 

serial data rate automatically adjusts to match

 

 

the modem-to-modem data rate

\Kn

n=0-5

Set break control, where n= 0 to 5. Default

 

 

is 5

\N_

\N0

Normal data-link only

 

\N1

Direct data-link only

 

\N2

MNP data link only

 

\N3

V.42/MNP/Normal data link

 

\N4

V.42 data link only

\O

 

Initiate reliable link during a normal link

\Q_

\Q0

Turn off flow control

 

\Q1

XON/XOFF software flow control

 

\Q2

CTS signal unidirectional hardware flow

 

 

control

 

\Q3

RTS/CTS signal bi-directional hardware

 

 

flow control

\Tn

 

Inactivity timer, where n = 0 to 90 minutes.

 

 

Default is 0

\U

 

Accept reliable link during a normal link

\V_

\V0

Do not send extended responses

 

\V1

Send extended response set 1

 

\V2

Send extended response set 2

\X_

\X0

Process XON/XOFF but don’t pass through

 

\X1

Process XON/XOFF and pass through

10

Page 30
Image 30
MaxTech V.42bis, V.32bis user manual Q3