Agitation

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Agitation

Spin

Windings

Wiring Harness Connections

Readings

Run Winding

Red to White or Black

1.5Ω

Start Winding

Yellow to Blue

3Ω

Over-load

White to Black

0 Ω

Note: Export Motors-run windings 4.9Ω, start windings 20.5Ω, over-load 0 Ω.