Disassembly Procedures

!WARNING

Note: If the fit between the right hinge ball and the lid is so tight you cannot press it into position with the right thumb, carefully strike the right corner of the lid with the palm of the hand to snap it into position.

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Tub Cover

1.Disconnect power supply to unit.

2.Secure Lid to the Top cover.

3.Remove Front Panel.

4.Remove screw securing Top cover to the cabinet.

5.Tilt Top backwards.

6.Remove tub cover by unsnapping the tabs securing Tub Cover to the Outer Tub.

Front Panel

1.Disconnect power supply to unit.

2.Remove two T-25H Torx screws securing front panel.

3.Pull front panel up and away from the bottom.

Balance Ring

1. Disconnect power supply to unit.

2. Remove Tub Cover.

3. Insert a pencil or other small pin through the three small holes in the outer tub depressing the tabs on the Balance Ring.

Top Cover

1.Disconnect power supply to unit.

2.Remove Front Panel.

3.Remove two top cover bolts and tilt Top Cover back.

Note: Hold lid closed or tape lid to the Top Cover to prevent it from striking the Control Panel.

22

16022842 Rev. 0

©2003 Maytag Appliances Company

Page 22
Image 22
Maytag MAT12PDD, MAT12PSB, MAT12PRB, MAT12PRA, MAT12PRD, MAT12PDS, MAT12PSA Tub Cover, Front Panel, Balance Ring, Top Cover