Maytag MAT12PRS Pressure Switch, Unbalance Lever and Plunger Assembly, Air Dome, Wrong, Right

Models: MAT12PDB MAT12PRB MAT12CSD MAT12PSA MAT13MNA

1 29
Download 29 pages 41.38 Kb
Page 19
Image 19
WRONG!

Disassembly Procedures

!WARNING

Reinstalling Lid Switch

1.Insert the lid switch assembly in the Top Cover (Push the switch assembly straight down and back until it locks in place).

WRONG!

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Pressure Switch

1.

Disconnect power supply to unit.

2.

Remove Control Panel.

3.

Disconnect wires attached to the switch.

4.

Remove clamp securing Air Dome Hose.

5.

Remove two screws securing Pressure Switch to the

Front Of Machine

Top

Cover

Top Cover.

RIGHT!

Top

Front OfCover

Machine

Unbalance Lever and Plunger Assembly

1.Disconnect power supply to unit.

2.Remove Lid and tilt the Top cover backwards.

3.Remove two screws securing the plunger assembly to the Top Cover.

Plunger Assembly

Air Dome

1.Disconnect power supply to unit.

2.Remove Control Panel and rear access service plate.

3.Remove clamp securing rubber hose to the Pressure Switch.

4.Remove clamp securing Air Dome to the Outer Tub spout.

Unbalance

Lever

©2003 Maytag Appliances Company

5.Disconnect rubber air tube secured to the cabinet.

6.Remove the air dome hose through the rear access opening.

16022842 Rev. 0

19

Page 19
Image 19
Maytag MAT12PRS Pressure Switch, Unbalance Lever and Plunger Assembly, Air Dome, Disassembly Procedures, Wrong, Right