Disassembly Procedures

!WARNING

Water Valve

1.Disconnect power supply to unit.

2.Remove screw holding Valve Bracket to back panel.

3.Pivot out until flange clears back and lift up to disengage the bracket from the slot on the back panel.

4.Remove two screws holding Water Valve to mounting bracket.

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

5.Remove Control Panel.

6.Remove screws securing console to meter case.

7.Remove two nuts (one inside coin box area and inside service access door compartment.).

Coin Slide

1.Disconnect power supply to unit.

2.Unlock and remove service access door.

3.Loosen the locking bolt from inside the meter case.

4.Pull the coin slide out of the Meter Case.

Note: The timer Actuator can be adjusted once the Coin slide is removed. The holes on the actuator are slotted to allow proper length adjustments (the actuator must be adjusted for the particular coin slide to advance the timer into the cycle).

Coin Drop Acceptor

1. Disconnect power supply to unit.

5.Disconnect wires from terminals.

6.Remove injector hose.

Meter Case

1.Disconnect power supply to unit.

2.Remove Service Access Door.

2. Unlock service access door.

3. Loose the two locking bolts from inside the meter case.

4. Remove Coin Drop Acceptor.

5. Remove screw securing Coin Sensor to the rear of the Coin Drop Acceptor.

3.Remove coin box.

4.Remove timer or disconnect wires to Service and Vault Switches.