Models: JS48FBDBDA JS42SEFXFA JS48CSDBDA JS48FBFXDA JS48CSFXFA JS48PPDBDA JS48SEFXDA JS42PPFXDA JS48FBFXFA JS48FWFXDA JS48FWDWFA JS48FWDWDA JS48CSDBFA JS48CSFXDA JS48CSDWFA JS42SEDBFA JS48FSDBFA JS48SEDBFA JS48FBDBFA JS48SEFXFA JS48FSDBDA JS48FWFXFA JS48FSFXFA JS42CSDWFA JS42FBDBFA JS42FSFXFA JS42FBDBDA JS42CSDBFA JS42FBFXDA JS42CSFXDA JS42FSDBFA JS42CSFXFA JS42FWDWFA JS42FBFXFA JS42FWDWDA JS42FWFXDA JS42FWFXFA RJRS4280B RJRS4271A RJRS4270C RJRS4270B RJRS4270A RJRS4280A RJRS4270D RJRS4280C RJRS4870A RJRS4281A RJRS4282B RJRS4280D RJRS4282A RJRS4281B RJRS4871B RJRS4870B RJRS4870C RJRS4870D RJRS4871A RJRS4872A RJRS4882A RJRS4872B RJRS4880C RJRS4880A RJRS4880D RJRS4880B RJRS4881A

1 80
Download 80 pages 26.32 Kb
Page 15
Image 15
PERFORMANCE DATA

PERFORMANCE DATA

Substance

Average

Influent

Product

Avg

NSF Reduction

Max.

Min. %

NSF

Reduction

Influent

Challenge

Water

%

Requirements

Effluent

Red.

Test

 

 

concentration

 

Red.

 

 

 

 

Chlorine Taste and Odor

1.9

2.0 mg/L

+

 

 

 

 

0.05

97%

> 50%

0.07

96%

508654-02

 

 

-+ 10%

 

 

 

 

 

 

Particulate

3233333

At least 10,000 particles/ml

74667

97.7%

> 85%

260000

92%

508534-02

Class I Particle size: <0.5 to < 1 um

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contaminent Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cysts*

109000

Minimum 50,000 /L

1

99.99%

99.95%

1

99.99%

508194-02

Turbidity

11.4

11 + 1 NTU

0.09

99.1%

0.5 NTU

0.11

99%

508533-02

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead, pH=6.5

0.15

0.15 mg/L

+

10%

0.001 mg/L

99.3%

0.01 mg/L

0.001

99.3%

506821-02

 

 

 

 

 

-

 

 

 

 

 

 

 

 

Lead, pH=8.5

0.15

0.15 mg/L + 10%

0.001 mg/L

99.3%

0.01 mg/L

0.001

99.3%

506822-02

 

 

 

 

-

 

 

 

 

 

 

 

 

Asbestos

236

107 to 108 fibers/L; fibers

0.18

99.92

0.18 x 107

0.18

99.92%

508495-02

 

 

greater than 10 um in length

 

 

 

 

 

 

Benzene

0.015

0.015 mg/L

+

10%

0.0016

89.6

0.0005

0.005

68.7

508494-02

 

 

+-

 

 

 

 

 

 

Carbofuran

0.082

0.080

+-

 

10%

0.001

98.8

0.001

0.001

98.8

508499-02

p-Dichlorobenzene

0.225

0.225

+-

10%

0.0005

99.8

0.075

0.0005

99.8

508498-02

Mercury @ pH 8.5

0.0059

0.006 mg/L+ 10%

0.00035

94.5

0.002

0.001

83.1

508496-02

 

 

 

 

-

 

 

 

 

 

 

 

 

Mercury @ pH 6.5

0.0059

0.006 mg/L

 

10%

0.0002

96.6

0.002

0.0002

96.6

508497-02

+-

* Based on the use of Cryptosporium parvum oocysts

Specifications CAUTION

After installing a new water filter, always dispense water for two min- utes before removing the filter for any reason. Air trapped in system may cause water and cartridge to eject. Use caution when removing.

The bypass cap does not filter water. Be sure to have replace- ment cartridge available when filter change is required.

If water filtration system has been allowed to freeze, replace filter cartridge.

If system has not been used for several months, or water has an unpleasant taste or odor, flush system by dispensing water for two to three minutes. If unpleasant taste or odor persists, change filter cartridge.

Manual background WARNING

To avoid serious illness or death:

Do not use refrigerator where water is unsafe or of unknown quality without adequate disin- fection before or after use of filter.

Systems certified for cyst reduc- tion may be used on disinfected waters that may contain filter able cysts.

The PuriClean® retractable water filtra- tion system uses a UKF7003AXX replace- ment cartridge. Timely replacement of filter cartridge is essential for perfor- mance satisfaction from this filtration system. Please refer to the applicable sec- tion of your Use and Care Guide for gen- eral operation, maintenance requirements and troubleshooting. Suggested retail price of replacement water filter is $39.99.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed above.The concentra- tion of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.

Specifications

Rated Flow:

.5 gpm (1.9 L)

Min. Op.Temp:

33° F (.6° C)

Max. Op.Temp:

100° F (38° C)

Min. Op. Press:

30 psi (207 Kpa)

Max. Op. Press:

125 psi (862 Kpa)

System tested and certified by NSF International against NSF/ANSI Std 42 for the reduction of Chlorine Taste and Odor, Particulate Class I and against NSF/ANSI 53 for the reduction of Cysts, Turbidity,Asbestos, Mercury, Lead, Benzene, p-Diclorobenzene, Carbofuran