2.Switch the power off. You have now set the test master.
3.Switch on the power supply to the slave speaker only while continuously pressing the Previous key on the MSR
1L 65
4. Switch the power off. You have now set the test slave.
If you now turn both speakers on, they will come up in Test mode.
To get back to normal user mode:
1. Switch on the power to each speaker with the Clear key pressed
ControlsTest mode |
|
|
|
|
|
|
|
|
|
Remote key | Logo | Input on | Control? | Channel |
|
| DSP5000 |
| selected |
|
|
|
|
|
CD | 1L | D1 | No | Left |
Radio | 1r | D1 | No | Right |
|
|
|
|
|
LP | 2L | D2 | No | Left |
|
|
|
|
|
Tape 1 | 2r | D2 | No | Right |
|
|
|
|
|
Appendix 3 Calibrate mode
WARNING: THIS MODE MAY CHANGE THE RESPONSE OF YOUR
SPEAKER, AND SHOULD ONLY BE USED BY A QUALIFIED SERVICE
ENGINEER.
The process of calibration is carried out during production; it alters the level of tweeter to compensate for the variability found in drive units. It should therefore only be used if a drive unit needs to be replaced.
The calibration levels are noted on the back panel.
To enter Calibrate mode:
1.Switch on the power supply to the speaker while pressing the Repeat key on the MSR
The calibration display looks like the Test mode display (see Appendix 2):
1L 65
This shows that you are in Calibrate mode and that the volume level is 65.
This mode operates like Test, but two menus are enabled.
DSP5000 User Guide