Component Specifications

ADA Scale: Inputs

A to D Scale Settings

20050929

CueStation INPUTS window

 

Digital Signal Level

 

Input Scale Setting

Input Signal

+ 6

 

 

+16

 

 

+26

dBu

 

 

 

 

 

 

 

+6 dBu = 1.55 Vrms

0 dBfs

 

-10 dBfs

-20 dBfs

2.2 V p-p

 

 

 

 

 

 

 

 

+16 dBu = 4.9 Vrms

 

 

 

 

 

 

 

CLIP

 

0 dBfs

-10 dBfs

6.9 V p-p

 

 

 

 

 

 

 

 

+26 dBu = 15.5 Vrms

 

 

 

 

 

 

 

CLIP

 

CLIP

 

0 dBfs

21.9 V p-p

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0dBu=.775Vrms

+4dBu=1.23Vrms

dBu = (20log)E1/E2

dBfs is dB full scale

IEEE Standard 754 32 bit floating point format

29

Page 29
Image 29
Meyer Sound LX-300 manual Digital Signal Level, ADA Scale Inputs