Component Specifications

LX-COS Comm/Sync

Provides a communications link to the CueStation host computer system (or the computer hosting your custom control software), a SMPTE Time Code signal generator and receiver, and MIDI I/O.

Ports

RS232 serial, RS422 serial, MIDI In/Out, XLR SMPTE In/Out

Pin-outs

Table 4. Nine-pin Male RS232 Serial Port (DTE)

Pin

Name

Use

1

 

 

2

RX

Receive data

3

TX

Transmit data

4

 

 

5

GND

Reference ground

6

 

 

7

RTS

Ready to send (not required)

8

CTS

Clear to send (not required)

9

 

 

Table 5. Nine-pin Female RS422 Serial Port (DTE)

Pin

Name

Use

1

 

 

2

RX

Receive data

3

TX

Transmit data

4

 

 

5

GND

Reference ground

6

 

 

7

RTS

Ready to send (not required)

8

CTS

Clear to send (not required)

9

 

 

Table 6. Five-pin DIN Female MIDI In

Pin

Name

Use

1

 

 

2

 

 

3

 

 

4

RD+

Receive data

5

RD-

Receive data