LX-300 Start Up Routine

Overview

7

A. Power-On Self Test

8

B. Hardware Initialization

8

C. System Firmware Startup

9

EtherTracks Startup

10

The LX-300 contains a digital signal processor and built-in software. When you power-on ("boot") an LX-300, this software is automatically loaded. During the boot, it performs a number of diagnostic tests, initializes the hardware, and loads the latest control software.

If the boot software encounters any non-recoverable (fatal) errors, it will attempt to display the error. The following boot sequence description should assist you in identifying at which point the error occurred and what caused it.

COS

 

 

ELC

 

LX-COS

 

 

LX-ELC

 

 

 

EtherTracks

 

ComSync

 

 

 

 

 

Ethernet Port

 

Serial Ports

 

 

 

 

 

 

 

 

PPC

ELC

 

 

 

RAM

DSP

 

 

ELC Boot Flash

 

EPROM

TI

DSP

 

 

 

320C6701

ELC

 

1.6.1

RAM

 

 

DSP

 

Operating System

 

 

 

 

Flash

 

 

 

 

ELC

 

 

DSP

 

IP Address Flash

 

 

 

 

 

Operating System Flash

 

 

 

User Boot Script Flash

 

 

 

 

User Project Flash

 

 

 

Overview

The LX-DSP module in the LX-300 does the following when powered-on:

A. Performs a Power-On Self Test.

B. Performs hardware initialization.

C. Reads the Frame ID switch setting on the LX-DSP, LX-EXP, and LX-VRA modules, and then for DSP IDs 01 through 32:

Loads and executes the system firmware program.

OR, if there is no system firmware, waits for system firmware to be uploaded.

7

Page 7
Image 7
Meyer Sound manual LX-300 Start Up Routine, Overview