3-RAID Control-LCD

6.3 Clear all Event Buffers

To clear all events in the system log, scroll to select the “Clear all Event Buffers” option and press ENT. The confirmation message will be displayed and press the ENT to clear all event buffers or ESC to abort the action.

6.4 Hardware Information

To view the RAIDBank4 controller’s hardware monitor information, Scroll to select the “Hardware Information” option and press ENT. All hardware information will be displayed. Scroll to browse all the hardware information. The Hardware Monitor Information provides the temperature, fan speed (chassis fan) and voltage of the internal RAIDBank4. The temperature items list the current states of the controller board and backplane.

The Platinum RAID has an audiovisual alert system to inform the user of environmental failure. The warning messages will indicate through the LCD, LED and alarm buzzer. The following is a table of monitoring threshhold values:

Monitored Item

Warning Condition

Controller Board Temperature

> 60° Celsius

Controller Fan Speed

< 1900 RPM

Power Supply +12V

< 10.5V

or

> 13.5V

Power Supply +5V

< 4.7V

or

> 5.3V

Power Supply +3.3V

< 3.0V

or

> 3.6V

CPU Core Voltage +1.2V

< 1.08V

or

> 1.32V

6.5 System Information

Choose this option to display Main processor, CPU Instruction cache/ and data cache size, firmware version, serial number, controller model name, and the cache memory size. To check the system information, press ENT to enter the main menu. Scroll to select the Show System Information option, and then press ENT. All major controller system information will be displayed. Scroll to browse all the system information.

RAIDBank4 Owner’s Manual

28

Page 28
Image 28