Miele DA 216-2 EXT, DA 219-2 EXT, DA 217-2 Appliance dimensions, Connection for air extraction

Models: DA 219-2 DA 217-2 DA 219-2 EXT DA 216-2 EXT DA 216-2

1 40
Download 40 pages 57.36 Kb
Page 21
Image 21
Connection for air extraction

Appliance dimensions

Safety regulations prohibit the fitting of this cooker hood over a solid fuel stove.

For safety reasons a minimum safe distance must be maintained be- tween the top of the hob / cooker and the bottom of the cooker hood:

450 mm above electric hobs / cookers

650 mm above gas hobs / cookers

650 mm above an open grill

from our range.

See "Warning and Safety instructions" for further information.

A distance of 650 mm may be prefer- able above electric hobs / cookers to give more working space.

When deciding dimension S ensure that the minimum specified safety dis- tance between the hob / cooker and the cooker hood is maintained. If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than ap- pliance height H.

Appliance height H:

DA 216-2

Extraction and EXT . . . . . 700* -940 mm Recirculation . . . . . . . . . 790 -1025 mm

DA 217-2

Extraction . . . . . . . . . . . . 710* -950 mm Recirculation . . . . . . . . . 800 -1035 mm

DA 219-2

Extraction and EXT . . . . . 730* -970 mm Recirculation . . . . . . . . . 820 - 1055 mm

*With air extraction to the rear through a wall the total height must be at least 790 mm.

To fit the tower, distance A between the top of the tower and the ceiling must be at least 20 mm.

The shaded area represents the wall or ceiling area for the vent cut-

out, for feeding the connection cable through to an external fan and for fitting the connection socket.

(For recirculation mode the connection socket may only be fitted in a wall area).

Connection for air extraction

ø150 mm or ø 125 mm with reducing collar.