Operation
Safety switch-off
Should the cooker hood be left on, the fan will switch off automatically after 10 hours. The lighting will remain on.
Pressing the On/Off button will switch the fan back on again.
Filter operating hours counter
The number of hours the cooker hood has been in operation is stored in memory.
The Grease filter symbol or the Charcoal filter symbol will light up to tell you that the filters need to cleaned or changed.
See "Cleaning and care" for further information about cleaning and changing the filters and resetting the operating hours counters.
Altering the grease filter operating hours counter
You can set the operating hours counter to suit the type of cooking you do.
The operating hours counter is set at the factory for 30 hours.
Select a shorter time of 20 hours if you fry a lot.
If you only cook occasionally, we still recommend 20 hours because grease which has built up gradually over a long period of time will harden on the grease filters and make cleaning more difficult.
If you use very little fat for cooking, select a longer time of 40 or 50 hours.
To alter the operating time:
Switch the fan off by pressing the On/Off button .
Press the
The Grease filter symbol of the operating hours button and one of the fan power levels will flash.
Fan power level indicator lights 1 to IS show the time set:
1. . . . . . . . . . . . . . . . . . . . . . . . 20 hours
2. . . . . . . . . . . . . . . . . . . . . . . . 30 hours
3. . . . . . . . . . . . . . . . . . . . . . . . 40 hours IS . . . . . . . . . . . . . . . . . . . . . . . 50 hours
Press the – symbol to select a shorter operating time or the + symbol to select a longer operating time.
Confirm your selection by pressing the operating hours button .
All the indicator lights will go out.
If you do not confirm within 4 minutes, the cooker hood will automatically revert to the original setting.