Miele DA 3590 EXT, DA 3560 Repositioning the venting connection, EXT models, Installation

Models: DA 3560 EXT DA 3560 DA 3590 EXT DA 3590

1 44
Download 44 pages 12.77 Kb
Page 28
Image 28
Repositioning the venting connection

Installation

￿Before installation, it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet.

This is particularly crucial when using the cooker hood at the same time as a heating appliance that relies on oxygen from the same room, which could result in the build-up of toxic fumes.

Repositioning the venting connection

The motor unit can be rotated to allow the vent ducting to be fitted at the back of the cooker hood.

This may be necessary if the cooker hood is being fitted in a reduced height wall unit, for example.

Repositioning is carried out before installing the cooker hood.

￿The cooker hood must be disconnected from the mains electricity supply.

￿Undo the fixing screws on the front panel of the cooker hood housing and remove the panel.

￿Undo the screws on the cover on the back of the cooker hood housing and remove the cover.

￿Unscrew the fixing screws on the motor unit.

￿Turn the motor unit towards the rear and position the exhaust socket in the exhaust vent on the back panel of the cooker hood housing. Ensure when turning the motor unit that the connection cable does not become detached.

￿Secure the motor unit in its new position.

￿Now secure the cover taken from the back panel to the top of the housing.

￿Refit the front panel and secure it using the screws.

EXT models

On appliances with an external motor (EXT models), the exhaust socket (not the motor unit) needs to be repositioned.

￿Unscrew the fixing screws and pull the top and bottom sections of the socket apart.

￿Position the top section of the socket over the exhaust vent on the back panel of the cooker hood housing and attach the bottom section to it from inside. Secure the exhaust socket with the fixing screws.

28

Page 28
Image 28
Miele DA 3590 EXT, DA 3560 EXT Repositioning the venting connection, EXT models, Installation