Miele DA 3590 Silencer, with air extraction, in recirculation mode, Connection for air extraction

Models: DA 3560 EXT DA 3560 DA 3590 EXT DA 3590

1 44
Download 44 pages 12.77 Kb
Page 40
Image 40
Silencer

Connection for air extraction

Silencer

(optional accessory)

To achieve even further reductions in noise levels, a special silencer can be fitted in the ducting system.

...with air extraction:

The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise).

For this reason the silencer must be positioned as close as possible to the ducting exit ￿.

...in recirculation mode:

The silencer needs to be positioned between the fan and the exhaust grille ￿. The space needs to be checked in some cases.

...air extraction with external motor:

To minimise noise from the motor in the kitchen, the silencer should be positioned in front of the external motor

￿if possible, or if the ducting is long, then in the ducting inside the cooker hood itself ￿.

In the case of an external motor placed inside the house, fitting a silencer behind the external motor ￿ reduces the noise of the motor outside the house.

In all modes of operation, the most effective noise reductions are achieved if two silencers are fitted one behind the other in the system.

40

Page 40
Image 40
Miele DA 3590 EXT, DA 3560 Silencer, with air extraction, in recirculation mode, air extraction with external motor