Switching the machine on and off

The following special functions can be programmed where appropriate:

1.Setting water inlet to level plus time control instead of timed inlet (60 secs).

If the inlet water pressure is lower than

2.5bar, too little water will flow into the wash cabinet. By selecting level plus time control flow, more water will flow into the wash cabinet, if there is an inlet water pressure between 1 and 2.5 bar.

The setting is adjusted separately for cold, hot and AD-water.

Switch off the machine.

1a. Cold water connection

Press T1 and c at the same time, hold them in and also swtich on the machine with "I-0".

The current programme status "P..." appears in the display.

Press F. "10" or "11" will appear in the display.

"10" = Cold water connection time control (60 secs)

"11" = Cold water connection level plus time control

Press c to change from "10" to "11" or vice versa.

Press h. "SP" appears.

Press h again. The change has been recorded and the display field clears.

1b. Hot water connection

Switch off the machine.

Press T1 and c at the same time, hold them in and also switch on the machine with "I-0".

The current programme status "P..." appears in the display.

Press E. "20" or "21" will appear in the display.

"20" = Hot water connection time control (60 secs).

"21" = Hot water connection level plus time control

Press c to change from "20" to "21" or vice versa.

Press h. "SP" appears.

Press h again. The change has been recorded and the display field clears.

1c. AD water connection

Switch off the machine.

Press T1 and c at the same time, hold them in and also switch on the machine with "I-0". The current pro- gramme status "P..." appears in the display.

Press D. "30" or "31" will appear in the display.

"30" = AD water inflow time control (60 secs)

"31" = AD water inflow level plus time control.

Press c to change from "30" to "31" or vice versa.

27

Page 31
Image 31
Miele G 7783 CD operating instructions 1a. Cold water connection, 1b. Hot water connection, 1c. AD water connection