5-10. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models

 

1 Remote Amperage Adjust

1

Receptacle RC13

Connect optional remote control to

 

 

RC13 (see Section 6-3).

Ref. 154 862-A / 048 720-K / 802 311

5-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models

New! LDR-14 long distance remote (includes 120 V receptacle)

OR

802 311

Socket*

Socket Information

A24 volts ac. Protected by circuit breaker CB5.

24 VOLTS AC

 

 

 

B

Contact closure to A completes

 

 

24 volt ac contactor control

 

 

circuit.

 

C

Output to remote control:+10

 

 

volts dc in MIG or Stick mode;

 

 

0 to +10 volts dc in TIG mode.

REMOTE

D

Remote control circuit common.

 

 

OUTPUT

 

 

CONTROL

E

DC input command signal: 0 to

 

 

 

+10 volts from min. to max. of

 

 

remote control with Voltage/

 

 

Amperage Adjust control at

 

 

max.

 

 

115 volts, 10 amperes, 60 Hz

 

I

ac. Protected by circuit breaker

115 VOLTS AC

 

CB6.

 

 

 

 

Contact closure to I completes

J115 volt ac contactor control circuit.

GND

K

Chassis common.

 

 

 

 

 

NEUTRAL

G

Circuit common for 24 and 115

 

 

volt ac circuit.

*The remaining sockets are not used.