B. Welding − CC/CV Models

Trouble

Remedy

 

 

No weld output; generator power output

Place Process/Contactor switch in a Electrode Hot position, or place switch in a Remote position and

okay at ac receptacles.

connect remote contactor to optional Remote 14 receptacle RC14 (see Sections 5-11and 7-1).

 

 

 

Check position of Ampere Range switch.

 

 

 

Check position of optional Polarity switch or Polarity/AC switch.

 

 

 

Reset circuit breaker CB11 (see Section 9-8).

 

 

 

Reset circuit breaker CB5 (see Section 9-8). Check for faulty remote device connected to RC14.

 

 

 

Check and secure connections to Remote 14 receptacle RC14 (see Section 5-11).

 

 

 

Have Factory Authorized Service Agent check connector board PC6 and connections.

 

 

 

Check fuse F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent check

 

brushes and slip rings, weld excitation circuit, field current regulator board PC1, and the rotor.

 

 

No weld output or generator power out-

Disconnect equipment from generator power receptacles during start-up.

put at ac receptacles.

 

 

 

 

Check fuses F1 and F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent

 

check integrated rectifier SR1, capacitor C9, field current regulator board PC1, and the rotor.

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.

 

 

Erratic weld output.

Check and tighten connections inside and outside unit.

 

 

 

Be sure connection to work piece is clean and tight.

 

 

 

Use dry, properly stored electrodes.

 

 

 

Remove excessive coils from weld cables.

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings.

 

 

High weld output.

Check position of Ampere Range switch and Voltage/Amperage Adjust control.

 

 

 

Check engine speed, and adjust if necessary.

 

 

 

Have Factory Authorized Service Agent check field current regulator board PC1.

 

 

Voltage/Amperage control does not

Place Ampere Range switch in lower range. Voltage/Amperage control does not work with Ampere

work when welding in Stick mode.

Range switch in highest range.

 

 

Low weld output.

Check engine speed, and adjust if necessary.

 

 

 

Check fuses F1 and F2, and replace if open (see Section 9-8). Have Factory Authorized Service Agent

 

check integrated rectifier SR1, capacitor C9, field current regulator board PC1, and the rotor.

 

 

Electrode sticks to the workpiece more

Circuit breaker CB4 may be open. CB4 automatically resets when the fault is corrected (see Section 9-8).

frequently during low voltage (short arc

Have Factory Authorized Service Agent check transformer T1 and integrated rectifiers SR4 and SR5.

length) conditions.

 

 

 

Low open-circuit voltage.

Check engine speed, and adjust if necessary.

 

 

No remote fine amperage or voltage

Place Voltage/Amperage Adjust switch in Remote position.

control.

 

 

 

 

Check and secure connections to Remote 14 receptacle RC14 (see Section 5-11).

 

 

 

Repair or replace remote control device.

 

 

Constant speed wire feeder does not

Reset circuit breaker CB5 or CB6 (see Section 9-8).

work.

 

 

 

 

Check and secure connections to Remote 14 receptacle RC14 (see Section 5-11).

 

 

 

Repair or replace wire feeder.

 

 

Low CV weld output.

Set Ampere Range switch to highest range.

 

 

Return To Table Of Contents

OM-4406 Page 51

Page 57
Image 57
Miller Electric Big 40 CAT manual Welding − CC/CV Models