4-3. Volt-Ampere Curves For CC Models

The volt-ampere curve shows the minimum and maximum voltage and amperage output capabilities of the welding generator. Curves of all other settings fall between the curves shown.

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ranges

 

 

80

 

 

 

 

 

210 − Max

 

 

 

 

 

 

 

165 − 350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 − 250

 

VOLTS

60

 

 

 

 

 

65 − 120

 

 

 

 

 

 

 

45 − 85

 

40

 

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

0

100

200

300

400

500

600

700

DC AMPERES

202 666-A