Miller Electric DS-64M Swingarc Setting Sequence Parameters, Sequence Parameters In a Program

Models: DS-64M Swingarc

1 60
Download 60 pages 43.89 Kb
Page 23
Image 23

SECTION 6 − SETTING SEQUENCE PARAMETERS

6-1. Sequence Parameters In A Program

. See Menu Guide for detailed programming steps.

Trim is arc length. If set to zero, arc length is short. If set to 99, arc length is long.

If time is set to zero in Weld sequence, welding continues until gun trigger is released.

If time is set to zero in any timed sequence except Weld, the sequence is skipped.

 

 

 

Trim

Volts

Inductance

IPM

Seconds

 

 

 

0-99

10.0-38.0

0-99%

50-780

 

 

1.

Weld

Pulse

X

 

 

X

0-100.0

 

 

 

 

 

 

 

 

 

 

MIG

 

X

X

X

 

 

 

 

 

 

 

 

 

 

 

2.

Crater

Pulse

X

 

 

X

0-5.00

 

 

 

 

 

 

 

 

 

 

MIG

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

3.

Burnback

Pulse

 

 

 

 

 

0-0.25

 

 

 

 

 

 

 

 

 

 

 

MIG

 

X

 

 

 

 

 

 

 

 

 

 

 

 

4. & 5. Postflow/

 

 

 

 

 

 

0-9.9

Preflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

Run-In

 

 

 

 

 

 

 

 

 

 

 

 

 

25-780

 

 

 

 

 

 

 

 

 

 

6.

Start

Pulse

X

 

 

X

0.00-5.00

 

 

 

 

 

 

 

 

 

 

MIG

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

X = Setting available.

Wire Speed

WFS

Weld WFS

 

 

Start

Preflow

Run-In

Time

Time

 

 

 

Preflow

Run-In Arc

Weld

 

Strike

 

Trigger

 

 

Pressed

 

 

Weld Time

0-100 sec.

 

Crater

WFS

Time

Burnback

Crater

Time

Postflow

 

Time

Time

 

Burnback

Sequence

Crater

Postflow

 

 

End

Trigger

 

 

Released

 

 