Miller Electric DS-64M Swingarc manual Security, Definable Values Standard, Motor

Models: DS-64M Swingarc

1 60
Download 60 pages 43.89 Kb
Page 29
Image 29

8-5. Security

.The security feature works only when a data card is inserted.

 

 

 

 

1

 

Press

 

 

 

 

Mode

 

 

 

 

Select

S eq u e n c e

> P r o g

1

Turn

5 Times

D ua l S c h d

L oc k

O f f

Unit

 

 

C a r d

 

 

On

 

 

 

 

 

> S ec u r i t y

 

 

 

 

 

 

Side Panel

 

 

 

 

Parameter

4

 

 

3

Select

 

 

 

 

 

 

 

The security feature allows a mini- mum and maximum range limit to be defined for Trim, inches per min- ute (IPM), and ShpArc (see Section 12).

When the security lock is Off, the full range of values is available for each parameter.

When the security lock is On, the range of values available for each parameter is the defined value plus or minus the defined range.

2

For example, if the IPM value is de-

fined as 125, and the range is de-

 

 

fined as 50, the actual range of

 

available IPM is 75 to 175 IPM (125

 

minus 50, and 125 plus 50).

 

1

Card Display

 

2

Moving Line

P r o g

1

L o c k

O n

>T r i m

5 0

R a n g e

0

Increase/

Side Panel

Parameter

Decrease

Select

P r o g

1

>L o c k

O n

T r i m

5 0

R a n g e

0

Increase/

Decrease

P r o g

1

>L o c k

O f f

 

 

Moving line is under value that can

be

changed. Change program

number to access desired program.

3

Lock On/Off

Toggles security feature On or Off.

Definable values are displayed

when Lock On is selected. Use side

panel controls to change values.

4

Trim And Range Display

5

IPM And Range Display

P r o g

1

 

L o c k

O n

L o c k

O n

 

T r i m

5 5

>T r i m

5 5

 

>R a n g e

0

R a n g e

0

 

I P M

2 0 0

 

 

 

 

 

Side Panel

Increase/

Parameter

Decrease

Select

 

5

 

L o c k

O n

 

T r i m

5 5

 

>R a n g e

1 0

 

I P M

2 0 0

 

 

 

 

 

Side Panel

 

Parameter

 

Select

6 ShpArc And Range Display

Definable Values (Standard

Motor):

Trim: 0−99 Range: 0−99

IPM: 50−780 Range: 0−780

ShpArc : 0−20 Range: 0−20

In the example displays, the

operator could change the value of

Trim to 55 and its Range to ±10.

T r i m

5 5

T r i m

5 5

R a n g e

1 0

R a n g e

1 0

> I P M

2 2 5

I P M

2 2 5

R a n g e

0

>R a n g e

0

 

 

 

 

Side Panel

Increase/

Increase/

 

Parameter

Decrease

 

Select

 

Decrease

 

 

 

 

 

 

 

6

 

T r i m

5 5

R a n g e

1 0

> I P M

2 0 0

R a n g e

0

 

 

Also, the operator could change the

value of IPM to 225 and its Range to

±100 IPM from programmed

values. If the range settings are left

at 0, the operator cannot change

values from those programmed.

T r i m

5 5

 

I P M

2 2 5

 

>P r o g

1

R a n g e

1 0

 

R a n g e

1 0

 

L o c k

O n

I P M

2 2 5

 

>S h p A r c

0

 

T r i m

5 5

>R a n g e 1 0 0

 

R a n g e

3

 

R a n g e

1 0

 

 

 

 

 

 

 

 

Side Panel

Side Panel

Parameter

Parameter

Select

Select

OM-1588 Page 25

Page 29
Image 29
Miller Electric DS-64M Swingarc manual Security, Definable Values Standard, Motor