4-12. Installing And Threading Welding Wire

 

Tools Needed:

3/16, 5/64 in

15/16, 3/8 in

Install wire spool. Ad- just tension nut so wire is taut when wire feed stops.

Pressure

Indicator

Scale

Pressure

Adjust

Install drive rolls.

Install wire guide.

NONCONDUCTIVE

SURFACE

No Wire Slip

.Be sure that outlet cable has proper size

liner for the welding wire size. When installing gun, position liner extending from outlet wire guide as close as pos- sible to drive rolls without touching.

Install gun. Lay gun cable out straight. Cut off end of wire. Push wire through guides up to drive rolls; continue to hold wire. Press Jog button to feed wire out gun.

NONCONDUCTIVE

SURFACE

Wire Slips

.For soft wire or small diameter stainless

steel wire, use 2 drive rolls and set drive roll pressure from 0 to a maximum of 4 on the pressure indicator scale (so that only the inner spring is compressed). This setting will generally give the best performance for these types of wires.

To adjust drive roll pressure, hold nozzle

about 2 in (51 mm) from nonconductive surface and press gun trigger to feed wire against surface. Tighten knob so wire does not slip. Do not overtighten. If contact tip is completely blocked, wire should slip at the feeder (see pressure adjustment above).

Cut wire off. Close cover.

Repeat for other side.

ST-152 564-B / Ref. ST-156 929 / Ref. SC-150 922 / Ref. ST-156 930 / S-0627-A

OM-1588 Page 16

Page 20
Image 20
Miller Electric DS-64M Swingarc manual Installing And Threading Welding Wire